Having problems with your Refrigerators ?

What is the low side pressure on the GDM-26 with the cooler running


Answers :

Repair Help & Product Troubleshooting for Refrigerators
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

What is the low side pressure on the GDM-26 with the cooler running


... True GDM-49FC Refrigerator Commercial

Traulsen UL2HT 4 drawer cooler...unit's digital temp control indicates unit is running at 42 to 45 degrees, (varifie this temperature)..compressor is cycling off before it can come down to adequate temperature..high-side and low side pressures are good..no voltage from control box to compresser..cannot determine what is shutting down the compressor..also, temp control has set point switch, but will not respon to attempts to adjust set point Questions: Is there a lockout module inside the sy


... Traulsen UL2HT Refrigerator

With compressor running, low side pressure starts out about 15 psi then goes to a little below zero. i have added r134 freon until low side reached 10 to 12 psi. pressure stays there for a while then goes back to just below zero.


Wow, it would seem like you have a leak there on the low side. You add and it goes goes back to equal on the low side again. The gauge could be off just a bit. Have you pulled a vacum test on the unit? Sounds like you should pull everything out, vac ... Frigidaire Gallery Series GLHS269ZDB 36" 26.0 Cu. Ft. Side-by-Side Refrigerator w/ 7 Button Dispense...

Frigidaire side by side not cooling at all... condensor fan and compressor both running, coils clean, evap fan running, cold control turns unit off and on, defrost timer was replaced, no frosted evap coils..?????????HELP.....NEED STEP BY STEP INSTRUCTIONS FOR TROUBLESHOOTING....PLEASE....THANKS,,,Also have a Kenmore freezer doing same thing...pressures on the freezer are: low side -10(vac) high side 100psi


First I will check the pressures , should be 25 low side and 140 high for freon 134a ,but if you have the same pressures in both sides , the compressor is not pumpping and has to be replaced,and if there is negative pressure in the low side and over ... Refrigerators

Yes i have a g e side by side refrigurator it was low on freon it takes 134a i was told it only takes about 8 to 10 oz of freon what should the low side pressure run at please


If its under five years its in warrenty, it takes less the 8-10. about 5.5 oz. ... GE (PSS26MSRSS) Side by Side Refrigerator

I have a older manittowoc ice machine model BY0454A and the low side is freezing up is it over charged, I checked the water pump, the siphon tube is not over flowing, what could be the problem the pressures when it is running are high side 210psi and the low side 43psi


... Refrigerators

I have a kenmore side by side refridgerator and to make a long story short I am not sure what the low side pressure needs to be when running


It should be between 25 and 30 psi and the high side about 160 psi (only with the r134 refrigerant). ... Refrigerators

Will not get cold. Pressures are 80 on low side 150 on high side but no force in cooler and only gets down to 55 degrees.


Hi,\015\012\015\012Do you have ice at the back of the freezer section. If you do defrost the unit and see if this makes a difference to the performance. If it behaves you probably have a defrost heater or defrost thermostat fault. If it f ... True GDM-47 Refrigerator

Fridge problems I have a hvac business for 30 years. but know little about fridges . my problem i have now is . it is fine and cooling but then just stops. when I put on gauges it has gone into a vaccum. prolly -20 on my gages in vaccum. when it is turned off it has about 50 lbs of pressure on gauges. I figured there was a blockage. I changed the filter drier. vaccumed down . filled with 134a . was doing great . running about 2 to 5 lbs of pressure low side. got freezer down to 15 degrees. I fig


Friend,ngfam1 At your service!Sounds like a Thermostat problem!How old is the appliance?If the appliance is 10 years old or more you may not be advisable to put good money into bad! New appliances are so much more ... GE GSS20IEPWW / GSS20IEPCC Side by Side Refrigerator

HELLO, I'M WORKING ON A SUB ZERO REFRIGERATOR,MOD.#532 SER.#M756509 [old timer] I AM GETTING A BIG ACCUMULATION OF ICE ON THE LOWER LEFT SIDE OF THE FRESH FOOD EVAPORATOR COIL AFTER 3 TO 4 MONTHS OF RUN TIME. I CLEAR THE COIL,AND A FEW MONTHS LATER THE PROBLEM RETURNS. THE F.F. TEMP IS ABOUT 45 DEGREES,AIR FLOW IS O.K.AND THE FREON LOW SIDE PRESSURE IS 4 P.S.I. FREON 12 WHAT COULD BE CAUSING THIS? APPRECIATE YOUR HELP.


Heat exchanger ... Refrigerators

I replaced the compressor on my refrigerator. There were no tags as to how much freon the system takes. So I added enough to bring the low side to 72 psi w/ a cabinet temp of 70 degrees. The high side pressure was about 100 psi and it was producing liquid. The low side psi I got off a pressure chart for 134a. The unit started to cool but only got down to 64 degrees. When the temp dropped the low side droped to about 60 psi. Before I charged the system I evacuated the system a couple of times. Th


**** boy. 72 psi on the low side?\015\012 It ain't an air conditioner. The low side should be never over 5 PSI. The whole system holds only arounf 4 ounces. What were ya thankin?\015\012LOL\015\012WOW you will be lucky if the reed valves ain't blown ... Refrigerators

Refrigerator what should the low side refrigerant pressure be on a refrigerator while it is running


0 to 3 pounds is normal. Much higher than 3 pounds would most likely be a weak compressor. A vaccum would indicate out of freon/leak or a restriction. ... Refrigerators

I need to charge a GDM 33 ....there are two tube ends extended to the front from the compressor area...which one is the low pressure side....the one on the left or the one on the right that goes into an expansion tube


... True GDM-33-SSL-54 Refrigerator

Need to know what the low side pressure should be at for a ''CREW'' reach in cooler that has a 1/4 hp compressor and takes 12oz of 134a?


Hi buddy should be 9 on the suction side and 16 on the hp side ... Refrigerators

My Evertar Wine Cellar has two sides. It takes a long time for the two sides to cool down to the temperature I set and then one side runs constantly even after it reaches the temperature. The side that is always running never gets any cooler than the temp it is set at with all that running. Can I fix it? The model number is HDC36SS.


... Refrigerators

TFX25VR 25.2 cu ft side by side fridge ice maker not making any ice. I believe it is due to low water pressure as the water dispenser water pressure is low. this refrigerator does not have a filter per GE. What could cause this? Thanks in advance, tom


... GE 25.2 cu. ft. Side-by-Side Refrigerator with Dispenser TFX25ARBWW

No refrigeration. low side pressure -15 vacuum, h...


... Refrigerators

I have a tecumsee compressor for a cold tray Mod # aea2410yxa. Its showing 60 psi on the high and low side. It tries to run for about 10 sec. the kicks out. the power keeps the cond. fan running and it has 120 to the common side of the compressor but shows nothing on the run or start sides. i replaced the relay and the overload, could the compressor be bad?


The compressor is kicking the thermal overload for some reason. Look on the compressor label. There is an LRA number there which is for "locked rotor amperage." 1 1/4 hp compressor for example has an LRA of 13.7 up to 16.9 amps depending on manufa ... Refrigerators

(Frigidair refrigerator R134a system) 3 months after a new compressor was installed it stopped cooling, it leaked. I found and repaired the leak. Then bought some automotive R134a it had dye,conditioner, and stop leak in it. I don't think it was made to be put in a refrigerator as at 175psi. high side and 10 psi. on the low side gave me about 10 inches of frost across the top of the evaperator. at lower pressure 150-90psi I get 0-5in of vacuum on the low side. and about 1 to 3 in. of frost on th


The stop leak probably stopped up your cap tube system and the filter drier.You can try by replacing the filter drier, vacuum the system to 500 microns and recharge.The automotive 134a is the same as any other 134a. ... Frigidaire Refrigerators

I have Whirlpool Gold Refrigerator side by side, Model# GC5SHEXNS05 Both side of the refrigerator stop make cooling, whenever I adjust the temperature back to recommended setting or whichever I prefer, it simply swith back to -70F for the freezer, and 70F for the cooler sider. try the quick cool setting, same result. the motor on the back is running, you can hear it running whenever I turn on the power on the temperture control setting module. any input is highly appreciated. you can always reac


Replace the control board part# 4334000 appliance parts pros the board goes bad if light bulbs blow out and theres a surge, but freezer still freezes ... Refrigerators

Hello, I have a True GDM-36 cooler and when I plug it in to power up the unit I can hear the compressor running and the cooler is trying to cool down, howver within 5 minutes the compressor stops running. I noticed when that when I plugged in the cooler the condensor fan never came on, could that be the problem?


... True GDM-26 Refrigerator

WORKED FINE FOR 6 YEARS. STOPPED REFRIDGERATING DURING PERIOD OF LOW USE - FURNISHED BUT VACANT HOUST. POWER TO UNIT GOOD. LIGHTS ON. COILS CLEAN. FAN RUNS. DON'T KNOW IF COMPRESSOR RUNS. CIRCULATED AIR IS NOT COOLED. OBVIOUSLY NO ICE PRODUCED. TRIED TURNING OFF FOR 2 DAYS THEN TURNED BACK ON AT MID TEMP SETTINGS - NO CHANGE; NO COOLED AIR BEING CIRCULATED. THIS IS A WHIRLPOOL SIDE BY SIDE, 25.4 CU FT, ICE COLLECTOR & DISPENSOR IN DOOR, MODEL GD5SHAXLT02, SN 4591203 REFRIDGERATOR. HAS


Hello there again sorry i got knocked off line could you reenter the chat session ... Refrigerators

The refrigerator is not cooling. It seems to be running, there is power, the unit kicks on and off, but the freezer and the cooler are both running higher temps than normal. Model: ED5CHQXKT03 Ser: SP4126551 Built: 10-03 Side by side


!st check to see if the compressor, the large metal,black motor in the back bottom is the part your hear clicking on = off. If it is you may have a bad relay, Very common repair. If its clicking unplug the refrigerator. remove the wire clip holding t ... Whirlpool 25.6 cu. ft. Side-by-Side Refrigerator with In-Door-Ice Dispensing System

Manitowoc Ice Machine Model SD0322A was left to run without water for about a day. It then started to slow down, taking about an hour to make a batch of ice. Now it is not making any more ice. The air aroud the condenser was about 84 degrees F when I took the following tests: while the machine was running the air around the condenser was 84 degrees F. During the freeze cycle the low side was 55 psig and remaind there. The high side was 290 psig and also remained there. when it moved to the har


Hi,\015\012Before you check anything else... check to make sure that the water is not siphoning out and there fore the sump is constantly filling...\015\012Also check that the float is shutting off and is not running water into the sump a ... Refrigerators

Frigidair split side by side refrigerator model #frs26kr4cq0 stopped cooling, unplugged the cord for 4 hrs, plug back in running and making ice again, then stop cooling again, what could be wrong? timer or low freon, if low freon how to recharged it thanks


... Frigidaire FRS26KR4A Side by Side Refrigerator

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.burberryscarf-outlet.com.co || Terms of Use || Contact || Privacy Policy