Having problems with your Refrigerators ?

Maytag Plus Refrigerator, Model MSD2556AEW Side by Side. Defrost control not working. how to check and repair. If jumper between terminals "L1 to Test" Defrost are OK. Using Amp. meter read 4.6 amp. Compressor Motor 1.9 amp, Automatic defrost not working. Org. ADC are SIEBE Appliance Controls PCB, where can buy it?


Answers :

Repair Help & Product Troubleshooting for Refrigerators
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Maytag Plus Refrigerator, Model MSD2556AEW Side by Side. Defrost control not working. how to check and repair. If jumper between terminals "L1 to Test" Defrost are OK. Using Amp. meter read 4.6 amp. Compressor Motor 1.9 amp, Automatic defrost not working. Org. ADC are SIEBE Appliance Controls PCB, where can buy it?


... Maytag MSD2656G Side by Side Refrigerator

GE Refrigerator Model No. TFX26KRDAWW on the freezer side will cool to 0 F and then warn to 50 F and stop cooling. The Defrost Timer and Defrost Thermostat have been replaced. When the compressor is running my AMP reading is about 1.5 and when the compressor is not running the reading exceed 15 AMPS.


Sounds like the compressor is going out. Most refrigerators will draw less then 11.2 amps. ... Refrigerators

Have kenmore 253.54622402 side by side--from the start-- ice in icemaker freezer 1/2 thawed-- compressor not working. started disasembled to check defrost timer--i found electrionic defroster - so that means no adjustments ? ...... ohm tested each thermostat / cold food side warm setting closed-- cold open /////// freezer thermostat warm - resistance on ohm meter-- and cold test still no diff - no open reading to shut down compressor ? assembled back -- restart system -- getting air from damp


" waited 1 hour freezer 20 degrees // cold food side 45 degrees and no air flowing from damper " As per this it indicates that the ventilations are getting blocked after few hours.First the air was flowing from damper but after one hour it stop ... Kenmore 53642 / 53644 Side by Side Refrigerator

GE side by side: Model GSL25JFPABS Does not defrost. Circulating fan is working. Heating element works when 110v is apllied to it. Points in thermostat are closed (freezer warm). Installed new circuit board Door gaskets sealing well. There is no way (I presume) to force the circuit board to bring on the defrost circuit. (unlike older timer motor). Without a wiring diagram I cannot check all components. My assumption is that the board cuts power to the compressor and then powers


... Refrigerators

Hi. My fridge stopped running altogether. Nothing is going on either side. No fans are going, inside or outside, compressor isn't hot. Thought might be in 'permanent' defrost mode...(?) When I turn the control knob to the fridge side all the way down, a motor seems to open/close a trap door at the far left corner, I assume controlling the amount of cold air that would come in from the freezer side...if the freezer worked... What would you think is going on, can I repair it myself, and/or i


Hi Sylvia - If your fridge is over 5 years old, replace it. The new ones are so much more inexpensive to operate that they pay for themselves in 2-3 years. Do not put 500 into a repair...........not worth it I assure you. Joe ... Frigidaire FRS23R4A Side by Side Refrigerator

My Whirlpool S X S model # ED25CQXFW02 (s/n # SJ2830116) .... will not freeze or cool.... cleaned coils etc....fan works..... then pluged it back in....worked fro one day...then everything thawed out again in freezer.... i think, after reading a bit...it is the overload, relay, or capacitor ?? looks like a litle black box on the side of the compressor but have no clue how to get it off and change.... seems easy...but won't come off? what am I not doing? also how do I check the amps on the c


Hi, sounds as though the compressor is going off on its overload, which would be telling us that you have a internal problem in the compressor. The little black box you see on the compressor is the electrical cover for the klixon over load and the st ... Whirlpool GS6NBEXR Side by Side Refrigerator

Everything works on fridge, compressor running fans, timer. The problem is it has to run constantly except for defrost cycle and freezer only gets to 25 degrees. Fridge side is about 40 but both thermostats are tuned up all the way. Recharge? I read this is uncommon but can/ ,t think of any other problem.


I had this fixed and it was the Defrost heater and the part that makes it come on he had to splice it in so I am glad I didn't try to do it my self parts and labor my bill was $168.00 ... GE (PSS26MSRSS) Side by Side Refrigerator

Ge side by side refrigerator........the fridge stopped working, there is power...i removed the bottom back panel and the fan that cools the compressor was making a clicking noise and the fan blade was barely moving (kinda like a clock ticking)....i thought it was probably the motor..... i disconnected the wired plug that goes from the motor to (i think) the compressor, then i reconnected and the motor (and fan) and the compressor kicked on and began to run normally........this also happe


Hi!!\015\012\015\012Make sure the condenser coil in front of the fan is clean. Also, make sure the fan is working strong, not just barely moving. The whole area can be cleaned using a vacuum with a brush adapter. When doing the condenser coil ... GE (PSS26MSRSS) Side by Side Refrigerator

GE GSS20IBMB fridge, a side by side. I opened it up (took off the cover in the freezer compartment) to see, and the coils are completely iced over. This happened before. Then, I defrosted it, and it lasted a couple of months before freezing over again. Is this most likely due to the defrost heater coils not working? The microprocessor? The compressor seems to work just fine; when it's defrosted no problem. Where can I get parts for this thing?


The evaporator coil behind the cover on the back wall inside the freezer will ice up under normal conditions. Every 8 to 10 hours for around 20 minutes the defrost timer (or in most newer models the electronic adaptive defrost control) will turn the ... GE (PSS26MSRSS) Side by Side Refrigerator

I HAVE A HOTPOINT HS25GFPD WW SIDE BY SIDE REFRIGERATOR THAT STOPED RUNNING. I REPLACED THE MOTHER BOARD BUT DID NOT WORK . I FOUND THAT WHEN THE J2 PLUG IN WAS REMOVED THE ICE MAKER MOTOR WORKED AND THE COMPRESSOR AND FAN BY THE COMPRESSOR RAN. CAN YOU HELP ME ?


I'm not saying I'm the best at this but I'm pretty good when it comes to the Mother Board.....what you have described is virtually impossible...unless you have purchased the wrong board.\015\012Please post the part number of the board you purch ... Refrigerators

Hi, I have a GS6NBEXRB02 side by side refrigerator. The problem is the ice dispenser is not working. Water dispenser works just fine. I read one solution was to remove the motor and let it dry. I will try that. But first, how do I remove the motor. Try taking it apart but the shaft is too long to remove it. Can you help.


... Whirlpool GS6SHAXLS Side by Side Refrigerator

I have a GE side by side refrigerator GSS22JEMB BB. The defroster heater was replaced. How do I know if the defroster is working properly. Can I manually manually make the fridge go into defrost mode? Also when I open the door, is the motor on the freezer side suppose to stop running? There is a valve on the top of the fridge, Is there suppose to be a stream of cold air comming out? It is currently having very little flow.


To go into defrost manually : Remove the 10"X13" panel from the back of the fridge . You will see a plug with 3 larger wires going to it . Unplug this plug ( UNPLUG THE REFRIGERATOR FIRST ) . The blue receptical will look like this wire#1,wire#2, spa ... GE (PSS26MSRSS) Side by Side Refrigerator

I have a 2001 Whirlpool Imperial Series side by side refrigerator. Yesterday white smoke was coming from out of the bottom left side of the refrigerator. We can not see anything though on inspection. However, there seem to be some burn marks on the relay switch attached to the compressor. We turned it back on and seemed to be working fine. This morning, everything was defrosting in our freezer and now the fan isn't working.


... Refrigerators

Whirlpool side by side refridgerator, 14 years old, nothing works. By passed controls-compressor fine, condensor fan works-no power to defrost timer, lights don't work. Power cord has continuity.


Go to the molex plug at the rear of the unit on the right side where all the wires connect check the white wire common wire\015\012loose common wire connection will not give you power to the nutral side for the freezer light defrost timer d ... Whirlpool Refrigerators

Kenmore refrigerator Sold my Kenmore refrigerator and they are saying it does not work at all. First they told me the refrigerator works and not the freezer. it is a side by side model 41514100 manufacturer date of 07/02 full load 6.5 amp. They are saying it is the compressor. They cleaned it underneath. It worked fine when it left my house. Any suggestions on what it might be other than that?


... Kenmore Refrigerators

I have a kenmore side by side refridgerator, model number 106.9535511. It is in great shape and was working great until yesterday. It quit working completely. The lights still work but the fans and compressor do not turn on at all. I know that it has an adaptive defrost control, cut I do not know what is causing it to not run. Should I start with the thermostat?


... Kenmore 25.1 cu. ft. Side-By-Side Refrigerator with Rotating Dispenser System

I purchased a used GE Profile TFX22PP Side by Siide which was working perfectly. I transported the item to my home, cleaned it, vaccummed the borrom coil and plugged it in. The unit has been running for about 14 hours and it is not cooling. The fan comes on, I believe I hear the compressor kick-in but the thermometer I placed into the Fridge (1 in the freezer side and one in the main side) are reading 78 Degrees. Lights come on, Fan is running and I believe the compressor also. What now?


... GE Refrigerators

Frigidaire Refrigerator/Freezer, Stainless Steel, side by side, purchased in 10-05...Not cooling at all, almost sounds like its not running... Everything is getting warm... We just had the motor compressor replaced 6 weeks ago...It almost seem like the same thing is occuring... Lucky for us, we have always been home and been able to get the food out etc... The compressor has a low humm and is not sounding like it is running at all... Very frustrating, reading the online complaints about this bra


When they replace the compressor they should have replace the overload and relay as well sounds like they did not\015\012 6 weeks should still be running\015\012i would call the poeple who diod the repair back out\015\012they have t ... Frigidaire PLHS269ZC Side by Side Refrigerator

Pts 25lhs ge fridge with top freezer. Freezer cycles to defrost up and down every few hours. not normal cycle for this unit. It has auto defrost, but this is messed up. I am a tech for delta airlines and have a lot of experience t/s heavy jet wires and computers (28 yrs). What can you tell me as to how I find a wiring schematic for this 5 yr old junker.I have cleaned the back side, cooling fins, etc.fan works,compressor works, fridge section seems to be stable. I don't want to spend much on this


Normal\015\012 0\015\012 \015\012 \015\012 \015\012 \015\012 \015\012 \015\012 \015\012 MicrosoftInternetExplorer4\015\012 \015\012\015\012\015\012\015\012\015\012\015\012 /* Style Definitions */\015\012 table.MsoNormalTable\015\012\011 ... GE Refrigerators

I have a GE side by side model #GSH25JSTA SS. It is 4 years old. The Water disenser stopped working about 6 months ago. We have replaced water filter and that did not seem to work. When we press the dispenser it sounds as though the water should be coming out but nothing actually does. I have read about water lines being frozen but I am not sure how to go about defrosting it without using a bunch of electricity by keeping the door open for hours. Advice?


... GE GSH25JSTSS Stainless Steel Side by Side Refrigerator

Im looking for the automatic defrost control location for a Frigidaire. Model # FRS6HR5HSB6, Serial # 4A80118247. My refrigerator compressor has stopped working for about 14 hours. I think it is stuck in the defrost cycle, I just want to advance it, so it will start working again. Until the service repairman can get here.


If your compressor is the only motor not working, meaning you also hear no other noises at all, advancing the defrost control out of defrost MAY solve your problem. However, if you do hear other motors running, then your refrigerator is not stuck in ... Refrigerators

Maytag model# MFD 2560HEW i live in old family farm house this is 2nd fridge in 30 days that stopped working the compresseror motor tries to come on inside light dims for split second i think the wall outlet is bad 112volts dont have amp meter to check my amp load do think the compressor or what burned out everything comes on like vit should but compressor will not stay on


... Maytag Refrigerators

Side by side freezer and ref, I have problem with the unit not producing ice, water stream seems so little, i tried to fill in the ice maker compartment with water and after an hour ice was produced but it was not ejected towards the ice container below. I tried to check the motor for and still working but it doesnt seem to work automatically, thanks


... Frigidaire FRS26R4A Side by Side Refrigerator

I have a Kenmore side-by-side model number 106.53669300 with an automatic ice maker. The problem is the ice maker is not working. I have 120 volts at the receptacle, but only 34 volts at the harness for the ice maker. I am confused because I can jumper out the motor and make the bail turn. The resistance heater also seems to be working. Once it has been jumpered, it ejects the ice, then fills and ejects the ice after it is frozen once more. It fills and freezes again but doesn't even try to ejec


HI. These symptoms seem to point to a failed thermostat. During this type of failure, the ice maker will not be able to regulate the freezing of the ice. It may not be able to preform a complete cycle, as well. The successful jumping indicates that t ... Refrigerators

I assume that the frig went into an apparent defrost mode and all refrigeration ended. There is a humming (solenoid type) in the small box on the side of the compressor on an intermittant basis (sounds like the compressor is working properly when the noise stops but then it starts again in a few minutes) This solenoid sound is a new sound which started yesterday Jul 23 and in the 12-15 hour period all of the frozen foods defrosted. I also noted that the pull out door is leaking a profuse


The noise you hear is the thermal overload ,as the motor cools it will click on ,then as the motor is worn out it draws current which causes the motor to get hot throwing the thermal switch to off again ,best advice is either a new motor or just scr ... Refrigerators