Having problems with your Refrigerators ?

My Whirlpool ED25TQ has stopped cooling on both sides and the fan does not run. The Lights turn on for both sides. I found the coils all full of dust and cleaned it out. How can I fix it?

\015 I found it was clogged so I vaccuumed it all out and I let the Frige sit then I tried to plug it back in and the fan doesnt turn on or the compressor, but the lights work on both sides.\015

Answers :

Repair Help & Product Troubleshooting for Refrigerators
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My Whirlpool ED25TQ has stopped cooling on both sides and the fan does not run. The Lights turn on for both sides. I found the coils all full of dust and cleaned it out. How can I fix it?


... KitchenAid Refrigerators

REFRIGERATOR AND FREEZER HOT, I HEAR SOMETHING CLICK ON THEN IT GOES OFF. I CLEANED UNDERNEATH BEHIND THE GRILL THE COIL THING WAS FULL OF DUST.


Sounds like the compressor starter relay ... KitchenAid Superba KSRG25FK Side by Side Refrigerator

M refrigerator isn't cooling the evaporator coil was full of dust it looked like it had a sweater over it but it still isn't cooling after I cleaned it what should I do


Don't you mean your CONDENSER (the black tubes found at the back of your unit or below it ? Those are the ones that dissipate the heat - if they are at the bottom, there is usually a fan blowing air on it, if applicable, check to see if it is spinn ... Kenmore 53092 / 53094 Side by Side Refrigerator

Found water on floor from drain tube under bottom of fridge. how do you clean dust off the bottom coils?


Your filter could be leaking and dripping into the drain pan , causing it to overflow . Replaceing the filter could be the solution as the rubber seals on the tips go bad . Pt. # 4396841 ... Whirlpool GS6NBEXR Side by Side Refrigerator

Hello, I have a model MTB2455AR in normal household use for about 9-10 years. Recently the cooling performance degraded rapidly. The frozen food started thawing and the main box went up to 50 degrees and the icemaker stopped making any ice blocks. The back of the freezer compartment was building up a layer of frost. We turned it off for a day and opened the lower back and found a lot of dust, lint, and pet hair. We cleaned off the coil and the fan and everything else we could reach easily


Hi,\015\012\015\012the fact that you found ice on the coils at the back of the fridge means that there is a problem with the defrost system.\015\012\015\012The defrost system ensures that coils are not icing up, and it is composed by a fa ... Refrigerators

I have a Whirlpool ED2SHAXMQ11 side by side refrigerator and the heat exchange coils under it are oriented in a 'V' shaped pattern from side to side making it impossible to get a vacuum cleaning head I have used before on other models back in there to get the dust off them. Over time the coils get dirty and that reduces efficiency and has to put a strain on the compressor as it runs more to make up the difference. Is there any way to clean these coils? Thanks


... Whirlpool ED2SHAXM Side by Side Refrigerator

Model #ED5PHAX5BO1 whirlpool fridge - the freezer is cold but the refrigerator is not. There uWAS some frost on the coils inside freezer and we defrosted. Also cleaned much dust off of coils underneat


Check to see if transfer fan is working from freezer compartment to fridge. You should hear it running when you open the fridge door. If not working, check fan and or control circuit ... Refrigerators

Evaporator fan my fan that blows on the evaporator coil seems to be running all of the time. I noticed that I had water in the drain pan so I cleaned it and while I was doing that I cleaned the vacuumed the dust and such off the coils. Now the drain pan is empty but I have a fan running all of the time. Any suggestions?


Check and make sure that you didn't knock a piece of insulation down onto the condenser fan when you were vacuuming off the coil. When the fan is blocked it can cause the compressor to what is called short cycle and the refer will never get up to tem ... Kenmore 53642 / 53644 Side by Side Refrigerator

FRS26HF5AB3 2002 model Freezer is not getting cold - cleaned coils and restarted unit and worked for 20 hrs. It is now at 38 f and going up.Noticed the problem three days ago when water was dripping out of the ice dispenser on the front of the unit. Found all of the ice inside melting. I checked the ice dispenser door and it is operating properly and not open at all. Pulled the unit out from the wall and unplugged the unit. I removed the cardboard and vacumned and cleaned the coils and everythin


Using the process of elimination, I restarted the unit a couple of more times and noticed a clicking sound from the compressor. I realized it was definately the compressor or one of its components. I purchased a "3 in one connector". Which in 75% of ... Frigidaire FRS26H5AS Side by Side Refrigerator

Refrigerator Sir my refrigerator not working. Yesterday when i was cleaned my refrigerator, i found the freezor is full of ice. So i cleaned freezor with the help of a knief for removing the ices, suddenly i heared a huge sound in the freezor that the knief got floor of the freezor and there is a small wound found and a huge collection of gas was gone, after that my refrigerator was not worked untill now. please give ur comments.


You need a qualified technician for the leak repair and recharging of refrigerant. All of the refrigerant in the system are gone, next time do not use sharp object when cleaning your fridge. ... Refrigerators

Hello i always surf the questions for my answers but now im stumped and about to call a repair person. I have the Ge bottom freezer fridge (pdf22mis/pdf22sis) My fridge and freezer temps are extremely high. I replaced the board, cleaned the coils in the back and the fan is working. I opened the freezer and found the evaporator coils had no frost. The tube going to the coils was frosted and the first 3 inches of the coil was frosted. the all fans are consistantly running and the compressor


It sounds like you have a restriction. Sometimes if you unplug the refrigerator for 24 hours or so it will break loose. If it doesn't then you will have to call in a repair tech to fix it. ... GE Refrigerators

GE TFX22PRXB, stopped cooling. Cleaned coils underneath, cleared blockage in freezer drain tube. Still would not cool. Removed panel from freezer and found lower set of coils frozen solid. Removed all ice with hair dryer, reassembled and still doesn't cool. Checked freezer this morning and lower coils were starting to freeze again, but only down the tube on the left side and the bottom two loops of the lower coil. What do I need to do?


... Refrigerators

How do you get in to clean dust off the condenser coils? On this model, the narrow grates across the front and back of the coils make it impossible to vacuum off the coils. It's not like most refrigerators where access to the actual coils is simple either from the front or back of the refrigerator.


I\\'ve been struggling trying to keep our 2 goldens dog hair from the coils of our 8 year old Kenmore side by side with "W" compressor coils, but like everyone else was unable to clean past the first set of coils.I came up with this s ... Estate TT18TKXKQ Top Freezer Refrigerator

The motor on the Kenmore refrigerator is running continuously. How do I stop it? I just cleaned out the dust from the coils underneath and replaced the kick-plate at the bottom


Hi: I've dealt with Kenmore for 30 years. Unfortunately the new model numbers don't reveal the age. I must assume it's a newer model. I'm not disputing what you said about it running all the time, but please read on. Oddly enough the new energy ... Kenmore 20.6 cu. ft. Top Freezer Refrigerator

Kenmore Coldspot 106-52609100 side by side is not working, freezer is only cold at the bottom and the refrigerator is not as cold as it should be. I opened the freezer to get something out and noticed the ice bucket was full of water and items on the top two shelves were thawing out. I cleaned everything out of both sides and cleaned the inside. I then removed both front panel and the back panel and cleaned all the coils with a shop vac. I noticed frost build-up on the back panel, I removed


No theres nothing else in line before the fan motor. If you have 120vac at the fan motor and its not running then either the bearings are tied up or your windings are open. Replacing the fan motor will correct the problem. Without that fan motor runn ... Refrigerators

Kenmore Coldspot 106-52609100 side by side is not working, freezer is only cold at the bottom and the refrigerator is not as cold as it should be. I opened the freezer to get something out and noticed the ice bucket was full of water and items on the top two shelves we thawing out. I cleaned everything out of both sides and cleaned the inside. I then removed both front panel and the back panel and cleaned all the coils with a shop vac. I has been setting closed for two days and still cold at the


HI, Can not type all the answers to you cause it is very log for me to do that.You can use this link to solve what ever problem you would want to check consigning you fridge. It will surely help you out.repai ... Refrigerators

GE Monogram ZIR36NDARH 36" built in fridge and freezer. Both are building up ice on evaporator coils behind vegetable bins. The ice is so thick the drawers hardly closed. I thawed them out with a hair drier last night. Turned unit back on and almost immediately the evap coils started to freeze up again. The condenser coils by the compressor were completely blocked with animal hair and dust. My father in law had never cleaned them in 10 years. He started to creep the temp up over the last couple


... GE Refrigerators

Noticed water under the fridge this morning and I opened up the freezer and noticed everything had thawed out and that it was not cold inside at all. Same with the fridge side . Not cold. So i pulled of the bottom cover in front and noticed a good inch of dust clinging to the coils so I cleaned them off and it still did not work so i opened the freezer and took off the back panel and coils are not frozen but noticed that the fan was not turning on.The motor above the coils in the freezer stoppe


There is a starting capacitor for the compressor. This is the clicking that you are hearing. If it is clicking and the lights are dimming then it is very bad news. The compressor is froze up. It is caused from not cleaning the coils regularly. ... Amana Refrigerators

Kenmore Coldspot 106-52609100 side by side is not working, freezer is only cold at the bottom and the refrigerator is not as cold as it should be. I opened the freezer to get something out and noticed the ice bucket was full of water and items on the top two shelves we thawing out. I cleaned everything out of both sides and cleaned the inside. I then removed both front panel and the back panel and cleaned all the coils with a shop vac. I has been setting closed for two days and still cold at the


Hi, all things been equal, since the compressor is working, the fan is in good shape but the freezer is only cold at the bottom while the fridge is not cool, then the problem is simple and straight forward.You need to refill the gas in your com ... Kenmore Refrigerators

Freezer is not as cold as it should be. Removed front bottom grill to try and clean condensor coils, but did not see any coils, only a couple of tubes. When I ran brush under fridge, it did not pick up any dust, pet hair, or anything. Does this model have covered condesor coils by chance? Thanks!


You can probably access the coils better from the back behind the cardboard cover. Make sure the fan near there is running when the compressor runs. You may have a defrost problem. The evaporator coil behind the cover on the back wall ins ... GE Americana A4425GDTWW Side by Side Refrigerator

I have a Magic Chef - Model # RB150AV - Serial # 11522453QF and it stinks. Clean out the drain pan. Vacuumed and cleaned out the coils and areas of compressor that had dust balls on it. It kind of smells like either stagnant water or burnt rubber. I went back to the same fridge about two hours after I cleaned it and still there. Any suggestions on what I need to look for?


... Magic Chef Refrigerators

Fridge completely stopped working. This happened a couple of weeks ago but after cleaning the dust off the coil, it worked again. However, this morning it went out again. Please help.


If you can tell me what model and make I can solve this for you, for example Frigidaire, GE, Whirlpool, Sears Brand that has different numbers like 159.58975\015\012Let me if this is a GE brand and model number, Thanks, Sea Breeze ... GE Refrigerators

The motor on the Kenmore refrigerator is running continuously. How do I stop it? I just cleaned out the dust from the coils underneath and replaced the kick-plate at the bottom


Modern refrigerators have an 85% run time ... Kenmore 20.6 cu. ft. Top Freezer Refrigerator

What's the easiest way to clean dust out from around coils and motor?Coils are sideways and access is very limited.


Use a leaf blower don in less than 5 min@@@@@ ... Whirlpool 25.4 Cu. Ft. Side-by-Side Refrigerator w/Thru-the-Door Ice & Water - Satina Stainless-Look

I have a True tbb-24-48g bar refrigerator that started tripping the breaker it was on. I removed the grille and the condenser coil fins were covered in a heavy layer of dust. I had not cleaned them for a couple of years, (dumb, I know). I cleaned them off but the compressor was extremely hot. I pulled the condensation tray and had a fan blow on it until it cooled to the touch in a couple hours. It still kept tripping the breaker. The next morning the breaker did not trip, so I figured I wa


Yes - you fried the compressor. The capacitor would be easy to see is bad if it had skewered it. Capacitors will actually blow up like a balloon. If you think it might be the capacitor - pull it and replace it but I can assure you - the compressor is ... True TBB-24GAL-48G Beverage Cooler

A detailed question is important to get you a relevant answers