Having problems with your Refrigerators ?

Defrost heating coil has .01 ohms restistance. Fridge does not defrost.


Answers :

That's not enough resistance, you need a new heating element. Word to the wise...replace the defrost thermostat while you're in there.
\015\012
\015\012You can find really good parts diagrams at searspartsdirect.com Make sure you have the complete model nujmber because they have over 7 million parts in their database.
\015\012
\015\012Hope that helps!

Repair Help & Product Troubleshooting for Refrigerators
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Defrost heating coil has .01 ohms restistance. Fridge does not defrost.


That's not enough resistance, you need a new heating element. Word to the wise...replace the defrost thermostat while you're in there. \015\012\015\012You can find really good parts diagrams at ... Kenmore 65234 Bottom Freezer Refrigerator

Coil in freezer icing up and auto defrost not working.the heat strip at bottom of coil is not going on and ice build up on coil cuts cold air supply to refigerated side of refrigerator.is there a sensor that could be bad?because i've had to manually defrost the coil in freezer section a few times and noticed that the heat strip at bottom of coil is not working properly.


Your\015\012 fridge is probably suffering from a defrost circuit failure. One (or \015\012possibly more) of the following components has failed: 1) the defrost \015\012terminator or sensor, 2) the defrost heating element or 3) the defrost \015 ... Amana ARS266ZB Side by Side Refrigerator

The freezer is cold, but the fridge wasn't. I took the back panel of the freezer off and there was ice on the evaporator coils. I defrosted the coils to remove the ice, and the fridge got cold. I understand that the problem may be the defrost timer, or the t'stat. Couldn't it also be the defrost heater (at the evaporator coils? I did a short test by turning the defrost timer until the compressor shut off and checking for heat at the evaporator coils (I can't see the heater from the access at t


... Amana ATB2135HR Top Freezer Refrigerator

Kenmore 25358082896 I used pressure air to clean under my side by side Kenmore 25358082896 fridge. my coils was frozed. deiced it. checked to defrosted relay that is connected to the coil by ohms using can of cold air it worked. put everything back. It defrosted a few times. Now the refrigerator side it not cooling as well again and the coil do not seem to be defrosting


... Kenmore 53642 / 53644 Side by Side Refrigerator

Defroster problems my defroster heating element is not heating and my coils are froze over. I talked to a tech who said I can jump a couple wires and put it into a test mode the only problem is I can not find how to get to circiut board. I took the panels off in the feezer and seen the temp sensor. so I need to know how to get to the board and also does the heating element use 120vac on both legs to heat or is it 120vac on one leg and the board sends a ground on the other? also the temp sensor o


How did you find this board that apparently no one can get to? I took apart most of the temperature control section and cant locate this infamous board. Please advise. ... Maytag MSD2756GES Side by Side Refrigerator

My GE TFX26GRDA side-by-side refrigerator periodically freezes up the coils so completely that no air circulates and the fresh food compartment gets WAY too warm. It does this over a period of anywhere between 4-12 months and has been happening since the unit was new. I just finished defrosting the coils with a hair dryer yet again. The defrost thermostat gave a resistance reading of about .5 ohm while frozen in ice; that is supposed to be normal. The heater coil works at least part of the time


Replace the defrost timer located in the upper area of the fresh food section with new timer part # AP2061695 its behind the cover in the fresh food section they do get intermittant in operation especially the timer motor inside this part ... Hotpoint HSS25GFT 25.0 Cu. Ft. Side-by-Side Refrigerator with GE SmartWater Filtration, LightTouch

GE MODEL GS-L25JFTBS, two years old. upper 2/3 of evap coil not clearing of frost. ice build up occurs over several weeks blocking air flow,causing fridge side to run too warm,also uper freezer compartment, too warm. must defrost with heat gun. defrost heater checks good, limit thermostat to heater is ok. just seems it does not defrost long enough to completely melt the ice, all the way to the top of evap coil. is this a computer issue, or is the upper temp sensor bad?


Hi, I take you ohm-ed out the defrost heater. The problem you are having is the defrost timer is faulty, causing it to ice up and doesn't defrost long enough.It wouldn't be a sensor, or computer issue. Normally, they are located at the b ... GE CleanSteel GSL25JFTBS

Whirlpool Model # GB2SHTXTS00 refrigerator not cooling. it has bottom freezer...coils in the freezer are icing up... I checked the heater, and stat ohmed ok.i ran the service test everything appeared good.. that really helped out.....thermostat was closed... heater heated up in forced deforst.. check the heater 30 ohms checked the stat 0.5 ohms.....the coils were slightly frosted over.. I thawed it several days back...wondering if it is gonna freeze up again??? and stop cooling the refrigerator.


Sounds like the defrost timer is not tracking the time properly. The unit needs to defrost once every 6-8 hrs. in order to work. Make sure the inside (evaporator) fan is running ok. If it rund for a few days and then warms up in the refrigerator sect ... Whirlpool GB2SHKXL Bottom Freezer Refrigerator

This is a old problem with maytag refrigerator, coil icing over I have changed the t'stat heating element assy,coil still ice over All fans are working, i removed adaptive defrost board and found it to be burnted by some resistors and I replaced with the substitute board (#61005899) but whe i turn on my temperature control nothing happens compressor will not start, so I install old burnt board and compressor starts it just wont activate the defrost cycle but ill do it if i jump it out by jumpi


Looks like the adaptive defrost board is a problem. The question is whether you had the correct replacement part. Best to confirm if the part shown ... Refrigerators

Hello, I have a problem with an LG fridge GRS392GCA. temperature inside the machine raises after a few hours. I discovered that the coil was totally surrounded by frost. I heated the frost. the fridge works now but frost seems to appear again around the coil. Would replacing this element :''LG Refrigerator Defrost Control Assembly'' http://www.espares.co.uk/part/fridges-and-freezers/lg/p/1084/81/0/0/639711/refrigerator-defrost-cont.html solve the pb ? what other elements of the defrost mechanis


Usually it is not the heater but the controller for the defrost.\015\012Which is a plastic package on the side if the coil, plugged into the roof.\015\012Replace it, they are not expensive and testing one is. ... Refrigerators

Freezer coils were a block of ice! Remover rear freezer panel, defrosted with heat gun. Freezer temp was set too high. Could this cause the icing? Shouldn't the defrost cycle have handled it? How do you test the defrost function? There is a timer somewhere. Also an actual heater?


An improperly sealing door gasket can cause that. Outside air will circulate past the coils and humidity in the air will condense and freeze there. Normal "defrost" generally cannot overcome that volume of ice. Additionally, the sensor on the coils i ... Amana ARB1917CSR Bottom Freezer Refrigerator

Frigidaire FRS26WRC defrost coil seems to be working overtime and heating up the freezer.


... Frigidaire Refrigerators

Hi, I have a defrost problem on my fridge/freezer, ie, the heating element doesn't seem to come on and so over a period of 2 weeks the coils clog up and the temperatures raise. My question is, is the defrost timer intergrated into the pcb on the back lower corner and will i need to replace it. thanks tim model s20d rbb32 and i think the board is 481221778178


Did you check your defrost heater and defrost bi-metal thermostat? what brand your fridge..i can't find out by model#, [email protected] ... Refrigerators

My Kenmore upright refrigerator-freezer, Model 55771, leaks water ocassionally out the left hand lower front corner of the freezer compartment as you face the doors. I already changed out the heating coils in the back of the freezer compartment that deice the cooling coils. A layer of ice forms on the bottom of the freezer, so I assume that things aren't draining properly during the defrosting cycle. The problem is so persistent that it has warped the plywood under the floor tiles. The unit


Remove rear bottom panel of unit. You will see the drain pan built on top of compressor. There should be water in here. If not, then the drain is plugged ... Refrigerators

I HAVE A ge tfx30pr and the frig is not getting very cold, freezer is nice and cold: here is what i know- i removed the back of the freezer, coils are not all frosted over (a finger size pc of ice at both lower corners) i ohmed out the defrost coils-ok. no blockage at either upper or lower vent. checking on the frig side, it appears that the damper will not open more than a little bit. any help would be appreicated.


If the evaporator coils are not frosted over, suspect either dirty condenser coil or shortage of gas. ... GE Refrigerators

GE TBX18SKE REFRIGERATOR IS AROUND 55F AND THE FREEZER IS AROUND 22F. I took the heating tube out and did a continuity test, tested good, visually it looks great. I cannot seem to locate the defrost timer. I put a new thermostat switch, the one that clips on the coils behind the freezer cover. I would just replace the heater and the defrost timer if I could just locate the darn thing, it doesn't seem to be behind the temp controls in the fridge either. Can anyone help?


Hi,As the weather is getting warmer for many people their freeze ... GE J Series 18.2 cu. ft. Top Freezer No-Frost Refrigerator TBX18AABWW

Where is the timer located on my general electric double door refrigerator is is model no. bsy25gfmdww, my coils are freezing up, the defroster isn't comeing on, I am having to use a heat gun to defrost every 2-3 weeks


The unit has a control board on  the rear of this model and that is what controls not only the defrost time but the compressor operation... there is also a defrost thermost on this unit that when reaches temperature it is connected to coil it ... GE GBS22HCP Bottom Freezer Refrigerator

My coil was iced up. I defrosted it. While I was in there I took a resistance reading on the defrost heater, it read 35 ohms. I am assuming it is good. Now what controls the heater and how can I check if it needs replacing.


If it's a glass heater you can look at it,if it's all black change it out,i've checked heaters that read good but it still needed to be replaced,like i said pull it out and do a visual look at it,if your machine has a timer,advance the timer by spinn ... Refrigerators

There is icing in freezer where the cooling coils are frozen solid & a warm refrigerator that lets the babies' milk spoil. Do I have a "black" heating coil? How can I tell? Is it the timer or the defrost control or all of the above? Where are they located?


Hi,Check out these tips...they can help you figure out whats going wrong with yourrefrigerator and why it is not coolingRefrigerator not Cooli ... Kenmore 57029 Side by Side Refrigerator

We tested the heating coil by: putting the probes in the pin connector for the black wire and the white/gray striped wire and it got continuity, the ohm meter beeped. Our ohm has 200 with the beep, 2k, 20k, 200k, 2000k + up - do you consider 200k to be Rx1 ? When we test the continuity of the element the reading is 22.3 @ 200k - we're assuming this means the element is good? We get no continuity reading on the black wire and the white wire - expected? is this ground ? Assuming we tested ev


> Our ohm has 200 with the beep, 2k, 20k, 200k, 2000k + up - do you consider 200k to be Rx1 ? \015\012\015\012The range designations are 'full scale' and with the normal range ending at 1999 for inexpensive meters, the 2K range ... Maytag MSD2756G Side by Side Refrigerator

The cooling coils are icing up. Have checked the defrost element with ohm meter it seems to be good. thermostat looks to be intact and sealed. Does this mean that I have a defrost control problem?


Checking defrost components on Maytag SideXSide refrigeratorsTo check the defrost circuit , unplug the refrig and inside the refrig section at the top about 2" in from each side in the back , there are "D" slots to put a finger in , and pull do ... Maytag MSD2756G Side by Side Refrigerator

I have a kenmore 795.75082401 fridge. it froze up and i defrosted the thing with a hair dryer. looks like the defrost coil got hot enough to start to melt the plastic cover and retain some of the aluminum heat sheild. Cooling fine now but when i tryed to adjust the temp it would not. I unplugged and replugged and the setting work again. Do you think its hanging in a cycle?


... Kenmore 18.3 cu. ft. Top Freezer Refrigerator w/Through-the-Door Water Dispenser

Freezer doesn't defrost, when i put an ohm meter to heating element it showed a direct short. I registered 70 volts to defroster. I can't find the schematic, whats the problem.


Normal\012 0\012 \012 \012 \012 \012 \012 \012 MicrosoftInternetExplorer4\012 \012\012\012\012\012\012 /* Style Definitions */\012 table.MsoNormalTable\012\011{mso-style-name:"Table Normal";\012\011mso-tstyle-rowband-size:0;\012\011mso-ts ... Roper RT14DKX Top Freezer Refrigerator

Refrig I have a side by side and the freezer keeps defrosting and leaving water at the bottom. The water then freezes leaving a sheet of ice at the bottom. I have seen the heating coil at the bottom back wall go on and cause this melting process. Question: Is there a timer/temp element that I need to look at? My impression is that the defrost cycle is coming on too often or staying on too long. Any ideas? Jerry


Defrost cycles normally are timed for 8 or 12 hour cycles. This would be normal. However the drain system on your freezer section is plugged. You have to defrost it and check the drain under the coil where you seen the heater on. Make sure it is not ... Frigidaire FRS26ZSG

GSS221BTA coils ice up. i defrost using heat gun. the coils freeze 2-3 weeks later


Check the thermostat is switching off at set temperature. Also check condenser clean ... GE Refrigerators