Having problems with your Refrigerators ?

Refrigerator compressor continously running thick ice forming at freezer

\015 Compressor won't stop,thick ice on freezer\015

Answers :

Repair Help & Product Troubleshooting for Refrigerators
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Refrigerator compressor continously running thick ice forming at freezer


... GE Refrigerators

Amana refrigerator side by side freezing on bottom on both sides. Food in upper part of refrigerator is warm. Ice melted in ice maker. Coils are clean. Compressor and fan are running. Compressor is hot to the touch. Fan in freezer is not running, although there is power to it. Unit is under 5 years old. Would this problem be with the thermostat or control board or am I way off base.


FOOD IN REFRIDGERATOR FREEZING AND WATER BUILD-UP ON THE CEILING OF THE REFRIDGERATOR,WHAT CAN I DO TO SOLVE THIS PROBLEM. ... Amana ASD 2624 Side by Side Refrigerator

Amana, bottom freezer, freezer not freezing and then refrigerator not keeping cool.. help Started with the ice maker not making ice, the sound of trying to pull water but never any ice. Then the freezer, all the food melted. You can hear the motor running almost non stop but nothing. Then last night, after we emptied the freezer, the fridge part started to warm up. Not it makes the odd buzzing sound like the compressor is trying but nothing is happening.


Hi\015\012Firstly put off the refrigerator before the compressor burns off.\015\012The problem is simple... the coling gas has leaked out.... put new coolong gas...BUT only after finding the place of leak... this will be needed to be fixe ... Amana ABB1927DE Bottom Freezer Refrigerator

We have GE Profile Refrigerator/Freezer(bottom section) model # PDS18LBMAWW. The Refrigerator section is room temp (temp control set to mid-point). The freezer section below is cold (ice cubes solid). I cleaned the very dusty compressor coil. Compressor fan is running and the compressor itself is running...I think. It is humming normally and with the lower back access panel off I can feel cold copper lines attached to the compressor unit. Do not feel any air circulating inside the re


I would assume you go into the fridge compartment and remove the inner panels,they may have screws or they may pop out(held with plastic clips.If you get to it defrost the coils and check for a drain that is frozen also.The food particles and such h ... Pds GE Profile Bottom-Freezer Drawer Refrigerator Energy Star 19.5 Cu. Ft. - PDS20MFS

My side by side refrigerator and freezer is not keeping cooling temperatures. Freezer had frost in ice dispenser, then began dripping water-had a few ice-sicles and then noticed food defrosting and frigerator not keeping food cold. No ice build up at compressor and fans are running...any ideas?


Hi, Many times a freezer and/or refrigeratordo not work right because of a dirty condenser coil...there are also many otherthings that can go wrong. \012If you are hearing a clicking or buzzing then check out thelast two tips. ... GE (PSS26MSRSS) Side by Side Refrigerator

Noise Recently can hear a "wind" noise coming from what seems to be the freezer side of the unit. Sounds like wind escaping thru a car window that is not completely closed. Noise goes up and down when compressor is running. Does not change when I open the door(s). Somewhat high pitched. Freezer side is not iced up, although ice crystals do form around the chute that dispenses the ice but not enough to interfere with operation.


Ok i had this same problem last week with one of my customers i check voltage at the evaporator harness at the mother board and every time the motor change speed the voltage increased i repl the board and also found the out was wire incorrectly check ... GE GSS20IEP Side by Side Refrigerator

Our freezer is not cold, food is defrosting, ice is melting. Refrigerator is working, freezer is not. We hear compressor running continuously. This is a side by side Amana model with water & ice maker built into door of freezer.


Look at the back of the freezer wall from inside the freezer. Is there frost on it? If there is, you need to replace one of the components of the defrost system. If there is no frost then you need to have a repair made to the sealed system, it is eit ... Amana 22.6 cu. ft. Side-By-Side Refrigerator with FrontFill Ice and Water

Ok, I am an Hvac tech, but I dont have a lot of exp with refrigeration. I am working on a reach in freezer, husseman mod HF82AT with 404 refrigerant. My question is what should a properly operating freezer give me in regards to pressures. I have a little froist forming on the compressor outlet which is not insulated. The unit runs continuously until defrost kicks it off, shouldn't it cycle when it reaches a certain temp?(there is no thermostat to adjust in this unit).


... Hussmann Refrigerators

Amana ARB2257CW...bottom freezer stopped working overnight...ice and ice cream found in liquid form...refrigerator seemed OK... this evening I unplugged unit for 25 minutes and plugged it back in...now fan is running constantly and refrigerator also seems to be getting warmer... any advice?... thanks...Jim


Sounds like a defective thermostat or it could be a defective defrost heater. If freon has not leaked from the frig its gonna be one of the two. BB ... Refrigerators

Amana side by side 11- 12 years old freezer not getting cold enough! vaccumed dust which was heavy from condenser at bottom of refrig ,compressor runing and copper lines from compressor one fairly hot and the other fairly cold, fan in freezer runs and cold air is blowing from fan vents only i belive its not cold enough, refrigerator side seems to be cold enough,ice maker not working water not coming in and not freezing. Need help- any ideas of what the problem may be?? yohojoe


... Amana AFD2535DES French Door Refrigerator

I have an Amana Distinctions Freezer on the bottom refrigerator. It is making louder and louder clunks, thunks, and a variety of noises. The freezer constantly has to be cleaned out as a sheet of ice forms in the bottom that is so thick I have to tap it to break it to take the ice out in CHUNKS regularly. I noticed it used to sound like it was "breathing", now it sounds like it's breaking into pieces.


It sounds like your defrost heating element may not be working and you should ck the drain line that takes defrosted water to the underside of the fridge. The defrost element is in the back of the fridge where your cooling coils are it will be a a bl ... Refrigerators

Jenn-Air French Door refrigerator.....frost forming on ice maker in bottom freezer compartment. Refrigerator cools normally. Freezer otherwise cooling normally also. Frost just started forming on ice maker and falls off when pulling freezer drawer open. We have NOT been using the ice maker. The freezer door is not ajar. The refrigerator is only 3 years old. No prior problems. I haven't cleaned the coils on the bottom for a while, however---but, I'm working on it now! Could the dirty


... Jenn-Air Pro-Style JFC2089H French Door Refrigerator

My Maytag refrigerator has condensation from the freezer running down into it, collecting on bottom of the freezer and dripping into the refrigerator portion.Both the refrigerator and freezer compartments are not keeping a cold temperature. I can hear it running, ice is still in the ice tray but as 1 big lump of ice. The model of my top-mount refrigerator is RTD 23. What should I do? Replace it or call a repairman?


... Refrigerators

Re: Kenmore Top Freezer formed ice, main refrigerator area is not cooling Kenmore Top Freezer (Main refrigerator area) is not cooling; This trouble shooting has happened for the past year. Main refrigerator area was either too warm or too cold and now, is not cooling period. A ***** of ice has formed in rear of the ice box. I removed ice maker and rear panel. Behind the panel was the unit/part that houses the refrigerant inside the aluminum piping and louvers. Ice was caked on throughout it.


Not easy to diagnose. the basic fault is that the defrost system has packed up.check that there is continuity thro the defrost heater. there may also be a thermal fuse in series with the heater so check that also.if those ok, ... Kenmore 18.3 cu. ft. Top Freezer Refrigerator w/Through-the-Door Water Dispenser

OK History on refrigerator Kitchenaid counter deapth side by side 25cf do not have model# it is 10yrs old and has had the compressor replaced under warrenty (3yr old). First problem small amount of ice in freezer for week then not fully cooling in freezer (@40 deg) frig (@60 deg) Here is the sequince of events, repair tech came over replaced defrost control board in freezer, no change exept running quieter. Next time tech replaced temp control board on refrig, no change. Technition is stumped as


Hi,\015\012 \015\012The water shut-off valve may not be fully open, check to see if your refrigerator is connected to a water supply cold water\015\012line only) and that the water shut-o ... KitchenAid Refrigerators

Ge TFL 27 FLL Side by Side Refrigerator. Seems to run too much and the freezer get too cold and the refrige seems to be too warm. After serveral days ice forms on the inside of the back wall, about the middle of the freezer, an the warm freezer alarm comes on. I have unplugged the unit for several hours and restarted. It will operate as above for several days and then this cycle starts over. Yesterday evening I did the Power Up Reset by simultaneously touching the SYSTEM CHECK & CRUSHED a


Defrost the whole thing clean all de-watering holes for defrosting.\015\012Cooling/freezing is provided by compresian of freon or ammoniagas and then rapidly expanding over an so called expansionvalve that can be frosted fixedd or malfunctionin ... Refrigerators

I have a Frigidaire Gallery refrigerator. It seems that there is ice forming behind the panel in the back of the freezer. When the freezer door opens, water slowly runs out the bottom of the freezer


... Frigidaire Refrigerators

Amana bb20v1ps Compressor and both fans are running on my bottom freezer amana. Fridge is warm, and air flow is weak from the damper. When I open the freezer door air flow increases in the refrigerator. I already opened up the back of the freezer, and removed two large blocks of ice on either side of the evaporator coil do you think I have a bad damper


... Amana Refrigerators

Amana French door, bottom mount freezer, Model AFD2535FES. Refrigerator and freezer are not cooling. Controls to set temperature of fridge and freezer (these are inside the refrigerator unit) appear to be working - that is, they are lighted and respond to changes in the settings. Fan appears to be running but compressor does not appear to start or run and refrigerator and freezer are not cooling at all. Is this possibly a control board issue or a compressor issue? If it is likely a control board


... Amana Refrigerators

Whirlpool refrigerator not cooling properly.The motor seems to be running. There is the sound of a fan in the freeaer. I cleaned underneath with a vaccuum and my compressor. I was going to take the back out of the freezer to see if the coils were iced up but can't get the rack out. I was going to defrost them with a hair dryer if they were. There is no condensation on the interior walls of the freezer. I live in the tropics and the food is spoiling. Please help. Thanks


Either the defrost timer, defrost heater or defrost termination thermostat have failed. The rack and the sheet metal at the back of the inside of the freezer would have to come out to access the evaporator coil.\015\012Need your model # to be a ... Whirlpool 21.0 cu. ft. Top Freezer Refrigerator with IceMagic Plus Ice Maker

22 cf kenmore side by side not very cold. Large ice block formed behind backplate on upper coils. thick frost on lower coils and on inside back of freezer section. Still making ice and fan blowing, compressor working. Could it be the door was not fully closed and allowed moist air to freeze and insulate the coils or is there another more likely cause?


... Kenmore 22.0 cu. ft. Side-By-Side Refrigerator with Filtered Ice and Water

My GE Profile side by side refrigerator has a slanted ice bucket in the freezer. The ice bucket is forming a long icicle on the bottom of it and the bottom two drawers in the fresh food side are freezing the vegetables. Has anyone run across this? And if so how do I solve this problem?


... GE Profile PSS26MGS Side by Side Refrigerator

Excessive water running down inside freezer and forming ice on freezer wall. Austec appliance your repair company in Austin worked on it twice and were unable. To fix it. How can we get it repaired we have no confidence in austic. The refrigerator works fine otherwise. William maurer512-263-4614


Do you have a ice maker on that side? If so the tray is not level or the water inlet is out of alignment. If not you more than likely have a air leak into the freezer at the top front gaskett but this usually shows up as frost. ... Refrigerators

I have a Whirlpool Gold refrigerator, built in 2000, that has a freezer over the fridge. On the inside of the fridge, near the ducts that go to the freezer, ice is continually forming and melting, flooding the bottom of the fridge. I think the drain pipe from the compressor may be clogged, since the pan is bone dry. I tried to check for a clog by blasting compressed air and by sticking a hanger up the line, but don't think I helped it at all. What do you think I should do?


Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube ... Refrigerators

I have a roper frost free refrigerator that was collecting ice below the heating element. I wrapped copper wire around the element to aid in preventing ice accumulation. Everything was fine. when i returned the freezer smelled hot and nothing was running. now the only thing that is working is the light in the fridge. Do fridges have a breaker or reset button on the compressor? Could I have blown the defrost timer or any other timer?


Could have damaged heater ... Refrigerators

A detailed question is important to get you a relevant answers